CyberPower UPS OLS Tower 10000VA/9000W
รหัสสินค้า: CBP-OLS10000E
GENERAL
Phase
Single Phase |
Form Factor
Tower |
UPS Topology
Online Double Conversion |
Energy Saving Technology
Online ECO Mode Efficiency > 96% |
Active PFC Compatibility
Yes |
Parallel Expansion (Max. Units)
4 |
INPUT
Generator Compatibility
Yes |
Nominal Input Voltage ( Vac )
230 |
Input Voltage Range ( Vac )
110 ~ 276 |
Adjustable Voltage Range ( Vac )
0~80% Load for 110 ~ 276 Vac |
0~100% Load for 176 ~ 276 Vac |
Input Frequency ( Hz )
50 ± 5 |
60 ± 6 |
Input Frequency Detection
Auto-sensing |
Rated Input Current ( A )
45.5 |
Input Power Factor
0.99 |
Input Connector Type
Hardwire Terminal Block |
OUTPUT
Capacity (VA)
10000 |
Capacity (Watts)
9000 |
On Battery Waveform
Pure Sine Wave |
On Battery Voltage(s) ( Vac )
208 ± 1% |
220 ± 1% |
230 ± 1% |
240 ± 1% |
Output Voltage Setting
Configurable |
On Battery Frequency ( Hz )
50 ± 0.1% |
60 ± 0.1% |
Output Frequency Setting
Configurable |
Power Factor
0.9 |
ECO Mode Voltage Tolerance
± 10 % |
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
105~125% Load for 10 min, 125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec |
Overload Protection (Battery Mode)
105~125% Load for 2 min, 125~150% Load for 30 sec, >150% Load for 1 sec |
Overload Protection (Bypass Mode)
125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec |
Crest Factor
3 : 1 |
Harmonic Distortion (Linear Load)
THD<2% |
Harmonic Distortion (Non-linear Load)
THD<5% |
Internal Bypass
Automatic Bypass, Manual Bypass |
Maintenance Bypass
Yes |
Outlet(s) - Total
1 |
Outlet Type
Hardwire Terminal Block x 1 |
Typical Transfer Time ( ms )
0 |
BATTERY
Runtime at Half Load ( min )
11 |
Runtime at Full Load ( min )
4 |
Typical Recharge Time ( Hours )
7 |
Maximum Charging Current ( A )
1 |
Start On Battery
Yes |
Smart Battery Management (SBM)
Yes |
User-replaceable
No |
Battery Type
Sealed Lead-acid |
Compatible Extended Battery Module (EBM)
BPSE240V47AOA |
Max. EBM Quantity ( pcs )
15 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
445 |
EMI/RFI Filtration
Yes |
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes |
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting |
LED Indicators
Line Mode, Battery Mode, Bypass Mode, UPS Fault |
HID Compliant USB Port(s)
1 |
Dry Contact (with Relay)
Optional |
Emergency Power Off (EPO) Port
Yes |
Audible Alarms
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault |
Management Cable ( pcs )
USB Cable x1 |
Power Management Software
PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
Metal |
Color
Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
10.24 x 27.87 x 21.65 |
Dimensions (WxHxD) (mm.)
260 x 708 x 550 |
Weight (lbs.)
189.6 |
Weight (kg.)
86 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
16.85 x 38.18 x 28.35 |
Dimensions (WxHxD) (mm.)
428 x 970 x 720 |
Weight (lbs.)
216.1 |
Weight (kg.)
98 |
ENVIRONMENTAL
Operating Temperature (°F)
32 ~ 104 |
Operating Temperature (°C)
0 ~ 40 |
Operating Relative Humidity (Non-condensing) ( % )
0 ~ 90 |
Operating Elevation ( feet/meters )
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 6000VA/5400W
รหัสสินค้า: CBP-OLS6000E
GENERAL
Phase
Single Phase |
Form Factor
Tower |
UPS Topology
Online Double Conversion |
Energy Saving Technology
Online ECO Mode Efficiency > 96% |
Active PFC Compatibility
Yes |
Parallel Expansion (Max. Units)
4 |
INPUT
Generator Compatibility
Yes |
Nominal Input Voltage ( Vac )
230 |
Input Voltage Range ( Vac )
110 ~ 276 |
Adjustable Voltage Range ( Vac )
0~80% Load for 110 ~ 276 Vac |
0~100% Load for 176 ~ 276 Vac |
Input Frequency ( Hz )
50 ± 5 |
60 ± 6 |
Input Frequency Detection
Auto-sensing |
Rated Input Current ( A )
27.3 |
Input Power Factor
0.99 |
Input Connector Type
Hardwire Terminal Block |
OUTPUT
Capacity (VA)
6000 |
Capacity (Watts)
5400 |
On Battery Waveform
Pure Sine Wave |
On Battery Voltage(s) ( Vac )
208 ± 1% |
220 ± 1% |
230 ± 1% |
240 ± 1% |
Output Voltage Setting
Configurable |
On Battery Frequency ( Hz )
50 ± 0.1% |
60 ± 0.1% |
Output Frequency Setting
Configurable |
Power Factor
0.9 |
ECO Mode Voltage Tolerance
± 10 % |
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
105~125% Load for 10 min, 125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec |
Overload Protection (Battery Mode)
105~125% Load for 2 min, 125~150% Load for 30 sec, >150% Load for 1 sec |
Overload Protection (Bypass Mode)
125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec |
Crest Factor
3 : 1 |
Harmonic Distortion (Linear Load)
THD<2% |
Harmonic Distortion (Non-linear Load)
THD<5% |
Internal Bypass
Automatic Bypass, Manual Bypass |
Maintenance Bypass
Yes |
Outlet(s) - Total
1 |
Outlet Type
Hardwire Terminal Block x 1 |
Typical Transfer Time ( ms )
0 |
BATTERY
Runtime at Half Load ( min )
18 |
Runtime at Full Load ( min )
7 |
Typical Recharge Time ( Hours )
7 |
Maximum Charging Current ( A )
1 |
Start On Battery
Yes |
Smart Battery Management (SBM)
Yes |
User-replaceable
No |
Battery Type
Sealed Lead-acid |
Compatible Extended Battery Module (EBM)
BPSE240V47A |
Max. EBM Quantity ( pcs )
15 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
445 |
EMI/RFI Filtration
Yes |
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes |
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting |
LED Indicators
Line Mode, Battery Mode, Bypass Mode, UPS Fault |
HID Compliant USB Port(s)
1 |
Dry Contact (with Relay)
Optional |
Emergency Power Off (EPO) Port
Yes |
Audible Alarms
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault |
Management Cable ( pcs )
USB Cable x1 |
Power Management Software
PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
Metal |
Color
Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
10.24 x 27.87 x 21.65 |
Dimensions (WxHxD) (mm.)
260 x 708 x 550 |
Weight (lbs.)
154.3 |
Weight (kg.)
70 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
16.85 x 38.18 x 28.35 |
Dimensions (WxHxD) (mm.)
428 x 970 x 720 |
Weight (lbs.)
180.8 |
Weight (kg.)
82 |
ENVIRONMENTAL
Operating Temperature (°F)
32 ~ 104 |
Operating Temperature (°C)
0 ~ 40 |
Operating Relative Humidity (Non-condensing) ( % )
0 ~ 90 |
Operating Elevation ( feet/meters )
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 3000VA/2700W
รหัสสินค้า: CBP-OLS3000EA
GENERAL
Phase
Single Phase |
Form Factor
Tower |
UPS Topology
Online Double Conversion |
Energy Saving Technology
Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
Yes |
INPUT
Generator Compatibility
Yes |
Nominal Input Voltage ( Vac )
230 ± 10% |
Input Voltage Range ( Vac )
190 ~ 300 |
Adjustable Voltage Range ( Vac )
0~50% Load for 110 ~ 300 Vac |
0~60% Load for 140 ~ 300 Vac |
0~80% Load for 160 ~ 300 Vac |
0~100% Load for 190 ~ 300 Vac |
Input Frequency ( Hz )
50 ± 10 |
60 ± 10 |
Input Frequency Detection
Auto-sensing |
Rated Input Current ( A )
13.04 |
Input Power Factor
0.98 |
Input Connector Type
IEC C20 |
Detachable Power Cord Plug Type
Schuko x 1 |
Power Cord Length (ft.)
5 |
Power Cord Length (m.)
1.5 |
OUTPUT
Capacity (VA)
3000 |
Capacity (Watts)
2700 |
On Battery Waveform
Pure Sine Wave |
On Battery Voltage(s) ( Vac )
208 ± 1% |
220 ± 1% |
230 ± 1% |
240 ± 1% |
Output Voltage Setting
Configurable |
On Battery Frequency ( Hz )
50 ± 0.5% |
60 ± 0.5% |
Output Frequency Setting
Configurable |
Power Factor
0.9 |
ECO Mode Voltage Tolerance
± 15 % |
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
>130% Load Immediately |
Crest Factor
3 : 1 |
Harmonic Distortion (Linear Load)
THD<3% |
Harmonic Distortion (Non-linear Load)
THD<5% |
Internal Bypass
Automatic Bypass, Manual Bypass |
Outlet(s) - Total
8 |
Outlet Type
IEC C19 x 1 | |
Hardwire Terminal Block x 1 | |
IEC C13 x 6 |
Outlet(s) - Battery & Surge Protected
7 |
Typical Transfer Time ( ms )
0 |
BATTERY
Runtime at Half Load ( min )
13.8 |
Runtime at Full Load ( min )
4.3 |
Typical Recharge Time ( Hours )
4 |
Maximum Charging Current ( A )
1.5 |
Start On Battery
Yes |
Smart Battery Management (SBM)
Yes |
User-replaceable
No |
Battery Type
Sealed Lead-acid |
Compatible Extended Battery Module (EBM)
BPSE72V40A |
Max. EBM Quantity ( pcs )
3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
370 |
EMI/RFI Filtration
Yes |
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes |
LCD Types
Color LCD |
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
1 |
Dry Contact (with Relay)
Yes |
Emergency Power Off (EPO) Port
Yes |
Audible Alarms
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
Power Cord x2, USB Cable x1 |
Power Management Software
PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
Metal |
Color
Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
7.72 x 12.27 x 16.38 |
Dimensions (WxHxD) (mm.)
196 x 337 x 416 |
Weight (lbs.)
57.2 |
Weight (kg.)
26.0 |
ENVIRONMENTAL
Operating Temperature (°F)
32 ~ 104 |
Operating Temperature (°C)
0 ~ 40 |
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 2000VA/1800W
รหัสสินค้า: CBP-OLS2000EA
GENERAL
Phase
Single Phase |
Form Factor
Tower |
UPS Topology
Online Double Conversion |
Energy Saving Technology
Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
Yes |
INPUT
Generator Compatibility
Yes |
Nominal Input Voltage ( Vac )
230 ± 10% |
Input Voltage Range ( Vac )
200 ~ 300 |
Adjustable Voltage Range ( Vac )
0~30% Load for 80 ~ 300 Vac |
0~50% Load for 120 ~ 300 Vac |
0~75% Load for 160 ~ 300 Vac |
0~100% Load for 200 ~ 300 Vac |
Input Frequency ( Hz )
50 ± 10 |
60 ± 10 |
Input Frequency Detection
Auto-sensing |
Rated Input Current ( A )
9 |
Input Power Factor
0.98 |
Input Connector Type
IEC C14 |
Detachable Power Cord Plug Type
Schuko x 1 |
Power Cord Length (ft.)
5 |
Power Cord Length (m.)
1.5 |
OUTPUT
Capacity (VA)
2000 |
Capacity (Watts)
1800 |
On Battery Waveform
Pure Sine Wave |
On Battery Voltage(s) ( Vac )
208 ± 1% |
220 ± 1% |
230 ± 1% |
240 ± 1% |
Output Voltage Setting
Configurable |
On Battery Frequency ( Hz )
50 ± 0.5% |
60 ± 0.5% |
Output Frequency Setting
Configurable |
Power Factor
0.9 |
ECO Mode Voltage Tolerance
± 15 % |
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
>130% Load Immediately |
Crest Factor
3 : 1 |
Harmonic Distortion (Linear Load)
THD<3% |
Harmonic Distortion (Non-linear Load)
THD<5% |
Internal Bypass
Automatic Bypass, Manual Bypass |
Outlet(s) - Total
4 |
Outlet Type
IEC C13 x 4 |
Outlet(s) - Battery & Surge Protected
4 |
Typical Transfer Time ( ms )
0 |
BATTERY
Runtime at Half Load ( min )
11.9 |
Runtime at Full Load ( min )
4 |
Typical Recharge Time ( Hours )
4 |
Maximum Charging Current ( A )
1.5 |
Start On Battery
Yes |
Smart Battery Management (SBM)
Yes |
User-replaceable
No |
Battery Type
Sealed Lead-acid |
Compatible Extended Battery Module (EBM)
BPSE48V40A |
Max. EBM Quantity ( pcs )
3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
345 |
EMI/RFI Filtration
Yes |
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes |
LCD Types
Color LCD |
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
1 |
Dry Contact (with Relay)
Yes |
Emergency Power Off (EPO) Port
Yes |
Audible Alarms
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
Power Cord x2, USB Cable x1 |
Power Management Software
PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
Metal |
Color
Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
5.9 x 8.9 x 15.5 |
Dimensions (WxHxD) (mm.)
151 x 225 x 394 |
Weight (lbs.)
37.3 |
Weight (kg.)
16.9 |
ENVIRONMENTAL
Operating Temperature (°F)
32 ~ 104 |
Operating Temperature (°C)
0 ~ 40 |
Operating Relative Humidity (Non-condensing) ( % )
20 ~ 90 |
Operating Elevation ( feet/meter
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 1500VA/1350W
รหัสสินค้า: CBP-OLS1500E
GENERAL
Phase
Single Phase |
Form Factor
Tower |
UPS Topology
Online Double Conversion |
Energy Saving Technology
Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
Yes |
INPUT
Generator Compatibility
Yes |
Nominal Input Voltage ( Vac )
230 ± 10% |
Input Voltage Range ( Vac )
160 ~ 300 |
Adjustable Voltage Range ( Vac )
0~50% Load for 110 ~ 300 Vac |
0~60% Load for 120 ~ 300 Vac |
0~80% Load for 140 ~ 300 Vac |
0~100% Load for 160 ~ 300 Vac |
Input Frequency ( Hz )
50 ± 10 |
60 ± 10 |
Input Frequency Detection
Auto-sensing |
Rated Input Current ( A )
6.5 |
Input Power Factor
0.98 |
Input Connector Type
IEC C14 |
Detachable Power Cord Plug Type
Schuko x 1 |
Power Cord Length (ft.)
5.9 |
Power Cord Length (m.)
1.8 |
OUTPUT
Capacity (VA)
1500 |
Capacity (Watts)
1350 |
On Battery Waveform
Pure Sine Wave |
On Battery Voltage(s) ( Vac )
208 ± 1% |
220 ± 1% |
230 ± 1% |
240 ± 1% |
Output Voltage Setting
Configurable |
On Battery Frequency ( Hz )
50 ± 0.5% |
60 ± 0.5% |
Output Frequency Setting
Configurable |
Power Factor
0.9 |
ECO Mode Voltage Tolerance
± 15 % |
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
>130% Load Immediately |
Crest Factor
3 : 1 |
Harmonic Distortion (Linear Load)
THD<3% |
Harmonic Distortion (Non-linear Load)
THD<5% |
Internal Bypass
Automatic Bypass, Manual Bypass |
Outlet(s) - Total
4 |
Outlet Type
IEC C13 x 4 |
Outlet(s) - Battery & Surge Protected
4 |
Typical Transfer Time ( ms )
0 |
BATTERY
Runtime at Half Load ( min )
14 |
Runtime at Full Load ( min )
4 |
Typical Recharge Time ( Hours )
5 |
Maximum Charging Current ( A )
1 |
Start On Battery
Yes |
Smart Battery Management (SBM)
Yes |
User-replaceable
No |
Battery Type
Sealed Lead-acid |
Battery Quantity (Each RBP) ( pcs )
3 |
Battery Voltage (Each RBP) ( V )
36 |
Compatible Extended Battery Module (EBM)
BPSE36V45A |
Max. EBM Quantity ( pcs )
3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
440 |
EMI/RFI Filtration
Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes |
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
1 |
Emergency Power Off (EPO) Port
Yes |
Audible Alarms
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
Power Cord x2, USB Cable x1, Phone Line x1 |
Power Management Software
PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
Metal |
Color
Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
5.94 x 8.86 x 15.51 |
Dimensions (WxHxD) (mm.)
151 x 225 x 394 |
Weight (lbs.)
33.73 |
Weight (kg.)
15.3 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
9.5 x 12.32 x 20.08 |
Dimensions (WxHxD) (mm.)
241 x 313 x 510 |
Weight (lbs.
(ราคายังไม่รวมภาษี)
CyberPower UPS OLS Tower 1000VA/900W
รหัสสินค้า: CBP-OLS1000EA
GENERAL
Phase
Single Phase |
Form Factor
Tower |
UPS Topology
Online Double Conversion |
Energy Saving Technology
Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
Yes |
INPUT
Generator Compatibility
Yes |
Nominal Input Voltage ( Vac )
230 ± 10% |
Input Voltage Range ( Vac )
160 ~ 300 |
Adjustable Voltage Range ( Vac )
0~50% Load for 110 ~ 300 Vac |
0~60% Load for 120 ~ 300 Vac |
0~80% Load for 140 ~ 300 Vac |
0~100% Load for 160 ~ 300 Vac |
Input Frequency ( Hz )
50 ± 10 |
60 ± 10 |
Input Frequency Detection
Auto-sensing |
Rated Input Current ( A )
4.5 |
Input Power Factor
0.98 |
Input Connector Type
IEC C14 |
Detachable Power Cord Plug Type
Schuko x 1 |
Power Cord Length (ft.)
5.9 |
Power Cord Length (m.)
1.8 |
OUTPUT
Capacity (VA)
1000 |
Capacity (Watts)
900 |
On Battery Waveform
Pure Sine Wave |
On Battery Voltage(s) ( Vac )
208 ± 1% |
220 ± 1% |
230 ± 1% |
240 ± 1% |
Output Voltage Setting
Configurable |
On Battery Frequency ( Hz )
50 ± 0.5% |
60 ± 0.5% |
Output Frequency Setting
Configurable |
Power Factor
0.9 |
ECO Mode Voltage Tolerance
± 15 % |
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse |
Overload Protection (Line Mode)
110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
>130% Load Immediately |
Crest Factor
3 : 1 |
Harmonic Distortion (Linear Load)
THD<3% |
Harmonic Distortion (Non-linear Load)
THD<5% |
Internal Bypass
Automatic Bypass, Manual Bypass |
Outlet(s) - Total
4 |
Outlet Type
IEC C13 x 4 |
Outlet(s) - Battery & Surge Protected
4 |
Typical Transfer Time ( ms )
0 |
BATTERY
Runtime at Half Load ( min )
15 |
Runtime at Full Load ( min )
5 |
Typical Recharge Time ( Hours )
5 |
Maximum Charging Current ( A )
1 |
Start On Battery
Yes |
Smart Battery Management (SBM)
Yes |
User-replaceable
No |
Battery Type
Sealed Lead-acid |
Battery Quantity (Each RBP) ( pcs )
3 |
Battery Voltage (Each RBP) ( V )
36 |
Compatible Extended Battery Module (EBM)
BPSE36V45A |
Max. EBM Quantity ( pcs )
3 |
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
440 |
EMI/RFI Filtration
Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes |
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
LCD Setting & Control
Mode Setting, Alarm Setting, Input & Output, Battery Setting |
HID Compliant USB Port(s)
1 |
Emergency Power Off (EPO) Port
Yes |
Audible Alarms
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
Management Cable ( pcs )
Power Cord x2, USB Cable x1, Phone Line x1 |
Power Management Software
PowerPanel Business (Recommended) |
SNMP/HTTP Remote Monitoring
Yes - with optional RMCARD205 |
PHYSICAL
Enclosure Construction
Metal |
Color
Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
5.94 x 8.86 x 15.51 |
Dimensions (WxHxD) (mm.)
151 x 225 x 394 |
Weight (lbs.)
28.88 |
Weight (kg.)
13.1 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
9.5 x 12.32 x 20.08 |
Dimensions (WxHxD) (mm.)
241 x 313 x 510 |